SAPCON - Grease Trap, Oil Seperator Monitor Equipment
SLC SERIES
Sapcon’s Capacitance Level Limit Switch utilizing specially designed Immuno Coat Probe offers a solution for level limit detection of fine, coarse, bulky solids, non-sticky slurries and liquids. The measuring system consists of an evaluation unit, an electronic insert and a probe. It basically works by using the dielectric property of the material.
Principle
The probe comprises of a sense electrode, electrically isolated from the metallic tank by means of a suitable insulator. The sense electrode and the vessel wall serve as the two electrodes of a capacitor with the service material as the dielectric. A change in material level causes a change in the dielectric, which in turn causes the value of this tank capacitor to change.

Features
Power Consumption – Less 05 VA
Power Supply – 24 V DC, 110 V AC, 220 V AC, 230 V AC & Universal (90-260 V AC)
Ignore build-up of material on vessel wall
High temperature durability (Up to 250°C and 600°C for non-conductive liquids)
Mechanical Spesifications
Probe Length
Rod Probes:
- 50 mm – up to 3000 mm
Rope Probes:
- Extend up to 400 mm to 12000 mm
Enclosure
- W: Weatherproof
- P5: IP-65 Weatherproof Housing
- FA: Flameproof for Gas Group IIA and IIB
Versions
- Integral type (Electronics Integral with probe)
- Remote type (Electronic separated by a 3 core ordinary cable)
Process Connection (Mounting Arrangement)
- Threaded Mounting: 1, 1-1/2”, 2” BSP / NPT
- Flanged Mounting: As per specification
- Tri-clover (As per specifications)
- SMS union coupling type
Insulation
- PTFE
- Ceramic
- Others
Wetted Parts and Mounting Material
- S4: SS-304
- S6: SS-316
- SL: SS 316L
Process Temperature
- A (Ambient): below 80°C
- H1 (High temperature): up to 150°C
- H2 (High temperature): up to 250°C
- H3 (High temperature): up to 600°C
Electrical Specifications
Input power supply & Outputs
- SLC 122/ 130: Single SPDT with (90-260 V AC) / 24 V DC
- SLC 222/ 230: Double SPDT with (90-260 V AC) / 24 V DC
- SLC 322/330: Single SPDT & Time Delay with (90-260 V AC) / 24 V DC
- SLC 622/630: Double SPDT & Time Delay with (90-260 V AC) / 24 V DC
- SLC 822: Double SPDT, Time Delay & two channels with (90-260 V AC) / 24 V DC
- SLC 922: Three SPDT, Time Delay & three channels with (90-260 V AC) / 24 V DC
- SLC 830: Double SPDT, Time Delay & two channels with 24 V DC
Power Consumption
- 05 VA
Fail-safe Setting
- Field selectable(through toggle switch)
- Open: Fail-safe High, Close: Fail-safe Low
Response Time
- 0.5 – 2 Sec
Time Delay Settings
- Cover and Uncover Delay: 0.5s to 60s, through potentio meter
Sensitivity Setting
- Field Selectable (through toggle switches)
Resonant Frequency
- 500 KHz
Applications Specifications
Application Material
For all Industries requiring level limit detection in Liquid Material Handling such as:
- Milk
- Water
- Diesel
- Fuel
- Juice
- Alcohol
- Chemicals
PDF Download