{"id":999,"date":"2017-01-10T17:48:01","date_gmt":"2017-01-10T17:48:01","guid":{"rendered":"http:\/\/www.maskamwater.com\/?page_id=999"},"modified":"2023-03-02T20:25:51","modified_gmt":"2023-03-02T20:25:51","slug":"turbine-step-vaults","status":"publish","type":"page","link":"http:\/\/www.maskamwater.com\/af\/products\/turbine-step-vaults\/","title":{"rendered":"Turbine STAP Kelders"},"content":{"rendered":"<div id=\"pl-999\"  class=\"panel-layout\" ><div id=\"pg-999-0\"  class=\"panel-grid panel-no-style\" ><div id=\"pgc-999-0-0\"  class=\"panel-grid-cell\" ><div id=\"panel-999-0-0-0\" class=\"so-panel widget widget_metaslider_widget panel-first-child panel-last-child\" data-index=\"0\" ><div id=\"metaslider-id-68\" style=\"width: 100%; margin: 0 auto;\" class=\"ml-slider-3-20-2 metaslider metaslider-nivo metaslider-68 ml-slider\">\n    <div id=\"metaslider_container_68\">\n        <div class='slider-wrapper theme-default'><div class='ribbon'><\/div><div id='metaslider_68' class='nivoSlider'><img src=\"http:\/\/www.maskamwater.com\/wp-content\/uploads\/2020\/12\/WebsiteBanner07-850x300.jpg\" height=\"300\" width=\"850\" title=\"WebsiteBanner07\" alt=\"\" class=\"slider-68 slide-6519\" \/><img src=\"http:\/\/www.maskamwater.com\/wp-content\/uploads\/2020\/12\/WebsiteBanner06-850x300.jpg\" height=\"300\" width=\"850\" title=\"WebsiteBanner06\" alt=\"\" class=\"slider-68 slide-6520\" \/><img src=\"http:\/\/www.maskamwater.com\/wp-content\/uploads\/2020\/12\/WebsiteBanner05-850x300.jpg\" height=\"300\" width=\"850\" title=\"WebsiteBanner05\" alt=\"\" class=\"slider-68 slide-6521\" \/><img src=\"http:\/\/www.maskamwater.com\/wp-content\/uploads\/2020\/12\/WebsiteBanner03-850x300.jpg\" height=\"300\" width=\"850\" title=\"WebsiteBanner03\" alt=\"\" class=\"slider-68 slide-6522\" \/><img src=\"http:\/\/www.maskamwater.com\/wp-content\/uploads\/2020\/11\/WebsiteBanner04-850x300.jpg\" height=\"300\" width=\"850\" title=\"WebsiteBanner04\" alt=\"\" class=\"slider-68 slide-6523\" \/><img src=\"http:\/\/www.maskamwater.com\/wp-content\/uploads\/2020\/11\/WebsiteBanner02-850x300.jpg\" height=\"300\" width=\"850\" title=\"WebsiteBanner02\" alt=\"\" class=\"slider-68 slide-6524\" \/><img src=\"http:\/\/www.maskamwater.com\/wp-content\/uploads\/2020\/11\/WebsiteBanner01-850x300.jpg\" height=\"300\" width=\"850\" title=\"WebsiteBanner01\" alt=\"\" class=\"slider-68 slide-6525\" \/><\/div><\/div>\n        \n    <\/div>\n<\/div><\/div><\/div><\/div><div id=\"pg-999-1\"  class=\"panel-grid panel-no-style\" ><div id=\"pgc-999-1-0\"  class=\"panel-grid-cell\" ><div id=\"panel-999-1-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"1\" ><div class=\"so-widget-sow-editor so-widget-sow-editor-base\"><h3 class=\"widget-title\">Turbine STAP Kelders<\/h3>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p>Zoeller Turbine STEP (Septic Tank Effluent Pump) Vaults provide an economical way of adding a filtered pump chamber to an existing single compartment tank, eliminating the need to install an additional pump tank.\u00a0 Each turbine STEP vault is designed for use in simplex or duplex high head pumping applications.\u00a0 With vault heights ranging from 51\u201d to 120\u201d, the turbine STEP vault can be customized for almost any project.\u00a0 Each turbine STEP vault includes a filter pack with a handle and a pump chamber.\u00a0 The filter pack utilizes the deep pleated filter design of Zoeller WW1 effluent filter, providing 928 linear feet of filtration area and a flow rate of 7,000 gpd.\u00a0 The filters screen solids to 1\/16\u201d.\u00a0 The vault\u2019s inlet can be factory cut or field cut by the contractor.<\/p>\n<ul>\n<li>Kluis hoogtes van 51&#034; 120&#034;<\/li>\n<li>Al die kelders pas in&#039;n 18&#034; septiese tenk opening<\/li>\n<li>Preassembled simplex of duplex pakkette met kontroles is beskikbaar<\/li>\n<li>Huisves \u00bd hp deur 3 hp, 11 deur 85 gpm turbine pompe<\/li>\n<\/ul>\n<p><strong>Notas<\/strong><\/p>\n<p><em>Alle Zoeller produkte moet ge\u00efnstalleer word en in stand gehou word in ooreenstemming met al die toepaslike kodes.<\/em><\/p>\n<p><em><br \/>\nLET wel: Le\u00eb tenks is ook beskikbaar vir veld ge\u00efnstalleerde inlaatgat.<\/em><\/p>\n<h4><strong>PDF aflaai<\/strong><\/h4>\n<p><a href=\"http:\/\/www.maskamwater.com\/af\/accordions\/products\/turbine-step-vaults\/\" target=\"_blank\" rel=\"noopener\">Turbine STAP Kelders<\/a>\u00a0- (1MB)<\/p>\n<\/div>\n<\/div><\/div><\/div><div id=\"pgc-999-1-1\"  class=\"panel-grid-cell\" ><div id=\"panel-999-1-1-0\" class=\"so-panel widget widget_sow-image panel-first-child panel-last-child\" data-index=\"2\" ><div class=\"so-widget-sow-image so-widget-sow-image-default-d6014b76747a\">\n\n<div class=\"sow-image-container\">\n\t<img src=\"http:\/\/www.maskamwater.com\/wp-content\/uploads\/2022\/07\/centrifugal-STEP-vault-211.jpg\" width=\"949\" height=\"2108\" srcset=\"http:\/\/www.maskamwater.com\/wp-content\/uploads\/2022\/07\/centrifugal-STEP-vault-211.jpg 949w, http:\/\/www.maskamwater.com\/wp-content\/uploads\/2022\/07\/centrifugal-STEP-vault-211-135x300.jpg 135w, http:\/\/www.maskamwater.com\/wp-content\/uploads\/2022\/07\/centrifugal-STEP-vault-211-461x1024.jpg 461w, http:\/\/www.maskamwater.com\/wp-content\/uploads\/2022\/07\/centrifugal-STEP-vault-211-768x1706.jpg 768w, http:\/\/www.maskamwater.com\/wp-content\/uploads\/2022\/07\/centrifugal-STEP-vault-211-691x1536.jpg 691w, http:\/\/www.maskamwater.com\/wp-content\/uploads\/2022\/07\/centrifugal-STEP-vault-211-922x2048.jpg 922w, http:\/\/www.maskamwater.com\/wp-content\/uploads\/2022\/07\/centrifugal-STEP-vault-211-5x12.jpg 5w, http:\/\/www.maskamwater.com\/wp-content\/uploads\/2022\/07\/centrifugal-STEP-vault-211-23x50.jpg 23w, http:\/\/www.maskamwater.com\/wp-content\/uploads\/2022\/07\/centrifugal-STEP-vault-211-600x1333.jpg 600w\" sizes=\"(max-width: 949px) 100vw, 949px\" title=\"sentrifugale-STAP-kluis-21[1]\" alt=\"\" \t\tclass=\"so-widget-image\"\/>\n<\/div>\n\n<\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Zoeller Turbine STEP (Septic Tank Effluent Pump) Vaults provide an economical way of adding a filtered pump chamber to an existing single compartment tank, eliminating the need to install an additional pump tank.\u00a0 Each turbine STEP vault is designed for<\/p>","protected":false},"author":3,"featured_media":0,"parent":13,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0},"wppr_data":{"cwp_meta_box_check":"No"},"_links":{"self":[{"href":"http:\/\/www.maskamwater.com\/af\/wp-json\/wp\/v2\/pages\/999"}],"collection":[{"href":"http:\/\/www.maskamwater.com\/af\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.maskamwater.com\/af\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.maskamwater.com\/af\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"http:\/\/www.maskamwater.com\/af\/wp-json\/wp\/v2\/comments?post=999"}],"version-history":[{"count":9,"href":"http:\/\/www.maskamwater.com\/af\/wp-json\/wp\/v2\/pages\/999\/revisions"}],"predecessor-version":[{"id":6658,"href":"http:\/\/www.maskamwater.com\/af\/wp-json\/wp\/v2\/pages\/999\/revisions\/6658"}],"up":[{"embeddable":true,"href":"http:\/\/www.maskamwater.com\/af\/wp-json\/wp\/v2\/pages\/13"}],"wp:attachment":[{"href":"http:\/\/www.maskamwater.com\/af\/wp-json\/wp\/v2\/media?parent=999"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}